The Diesel Generator Set Genergy GDS200T 204 kVA has a weight of 2650 Kg, a fuel consumption of 10.70l/h - 21.20l/h - 32.10l/h - 42.60l/h at 25% 50% - 75% - 100% of its power respectively. It has a three-phase current type and a frequency of 50 Hz.
This generator has a displacement of 8820 cc, an average acoustic pressure of 75 dB, and an electronic stabilization system "AVR ". It is equipped with a copper coil and has dimensions of 3450x1350x1850 mm.
The Diesel Generator Set Genergy GDS200T 204 kVA with a rated power of 185 kVA / 148 kW, a maximum power of 204 kVA / 163 kW, and a voltage of 400 V. It has a fuel tank capacity of 400 L.
GENERATOR MODEL | GDS200T (REF 21115) |
Stabilization system | AVR" electronics |
Voltage - Frequency | 400V - 50Hz |
Maximum Power | 185kVA (148kW) |
Nominal Power | 204kVA (163kW) |
Power Factor | 0.8 |
Nominal current | 267 A |
Average sound pressure at 7Mts LpA | 75 dB |
Guaranteed sound power level LwA 2000/14/EC Amendment 2005/88/EC | 97 dB |
Start-up type | Electric |
Fuel tank capacity | 400 L |
Fuel consumption 25% 50% 75% 100% (L/H) | 10.70 - 21.20 - 32.10 - 42.60 |
General protection degree | IP23 |
Dimensions | 3450x1350x1850 mm |
Weight | 2650 Kg |
ALTERNATOR | SINC274DX |
Nominal speed - Number of poles | 1500RPM - 4 |
Excitation system | Self-excited |
Phases | Three-phase |
Total harmonic distortion | No load |
Telephone interference | >2% |
Efficiency | 92.5% |
Insulation grade | H |
Degree of protection | IP23 |
MOTOR | GENERGY-SDE6120ZLDT |
Displacement | 8820 cc |
Speed control | Electronic |
Number of cylinders and arrangement | 6 in line |
Injection system | Direct |
Aspiration | Turbocharged |
Cooling system | Water |
Diameter X Stroke | 120x130 mm |
Engine power | 169 kW |
Lubrication oil capacity | 24 L (SAE10W40) |
Coolant capacity | 45 L |
IMPORTANT NOTICE |
It is mandatory for the customer to check oil and grease levels before start-up. If it is not possible to check the goods at the time of receipt, it must be indicated on the carrier's sheet that the customer is in agreement unless an examination is pending. |