Liquid Extractor-Injector Kit Anova
- Liquid extractor-injector kit Anova
€28.70 VAT incl.
The Diesel Generator Set Genergy GDS350T 358 kVA, its dimensions are 4000x1400x2000 mm, has a three-phase current type, a fuel tank capacity of 800 L, and with a displacement of 11720 cc.
This machine has an average sound pressure of 75 dB, a rated power of 325 kVA / 260 kW, a maximum power of 358 kVA / 286 kW, with a frequency of 50 Hz. It has a copper coil and weighs 3500 kg.
The Diesel Generator Set Genergy GDS350T 358 kVA has an Electronic stabilization system "AVR", a voltage of 400 V and a fuel consumption of 19.40l/h - 39.30l/h - 57.30l/h - 77.70l/h at 25% 50% - 75% - 100% of its power respectively.
GENERATOR MODEL | GDS350T (REF 21145) |
Stabilization system | AVR" electronics |
Voltage - Frequency | 400V - 50Hz |
Maximum Power | 325kVA (260kW) |
Nominal Power | 358kVA (286kW) |
Power Factor | 0.8 |
Nominal current | 469 A |
Average sound pressure at 7Mts LpA | 75 dB |
Guaranteed sound power level LwA 2000/14/EC Amendment 2005/88/EC | 97 dB |
Start-up type | Electric |
Fuel tank capacity | 800 L |
Fuel consumption 25% 50% 75% 100% (L/H) | 19.40 - 39.30 - 57.30 - 77.70 |
General protection degree | IP23 |
Dimensions | 4000x1400x2000 mm |
Weight | 3500 Kg |
ALTERNATOR | SINC4EX |
Nominal speed - Number of poles | 1500RPM - 4 |
Excitation system | Self-excited |
Phases | Three-phase |
Total harmonic distortion | No load |
Telephone interference | >2% |
Efficiency | 93.5% |
Insulation grade | H |
Degree of protection | IP23 |
MOTOR | GENERGY-SDE6MJ480L-D20 |
Displacement | 11720 cc |
Speed control | Electronic |
Number of cylinders and arrangement | 6 in line |
Injection system | Direct |
Aspiration | Turbocharged |
Cooling system | Water |
Diameter X Stroke | 138x145 mm |
Engine power output | 321 kW |
Lubrication oil capacity | 28 L (SAE10W40) |
Coolant capacity | 66 L |
IMPORTANT NOTICE |
It is mandatory for the customer to check oil and grease levels before start-up. If it is not possible to check the goods at the time of receipt, it must be indicated on the carrier's sheet that the customer is in agreement unless an examination is pending. |
Data sheet
Specific References