Pressure washer Anova H2200
The pressure washer Anova H2200 It has a electric motor, this engine provides a maximum power of 2.2 kW at a frequency of 2900 rpm.
This pressure washer includes as standard the 3WZ-18070B pump, what it offers us a maximum pressure of 80 bar. In addition to having a flow rate of 12.8 L/min.
The main uses of these pressure washers are maintain and wash vehicles and machinery agricultural or architectural. In addition to being able to wash, disinfect, and sanitize Any surface or environment.
Characteristics
Power |
2200 W |
Flow |
12.8 L/MIN |
Pressure |
80 bar |
Hose length |
8 M |
RPM |
2900 |
Dimensions |
580 X 420 X 395 mm |
Weight |
33 KG |
Operation of the pump
To use this machine, the first thing we need to do is change the oil filler cap, as the red cap included is only used for transportation. Next, we will put the yellow or brass cap what our pressure washer includes.
Next, we will regulate the pressure moving away from the surface to exert less pressure on it, we warn that increasing the factory pressure can damage the pump. For a Higher pressure will change the 40º nozzle. since it generates less pressure but with a wider stream.
We will regulate the pressure of the pump by turning the knob counterclockwise to decrease it and clockwise to increase it. This The knob should not be turned beyond the stop line..
Depending on the nozzle we use, we will exert greater pressure by decreasing the spray diameter and vice versa. The Changing nozzles is very simple., we just have to turn off the engine, pull back the quick setup, and insert the new one. Then we will ensure that the quick coupling is engaged.
If the The nozzle is clogged with dirt., the pressure level can be exceeded. We will solve it by cleaning the nozzle immediately using the nozzle kit supplied as standard in the following way:
- Turn off the unit and shut off the water supply.
- Pull the trigger of the gun to relieve the water pressure.
- Disconnect the gun's lance.
- Remove the nozzle from the lance. Clear any obstructions with the provided nozzle cleaning tool and rinse with clean water.
- Direct the water supply to the end of the spray rod to remove particles for 30 seconds.
- Reassemble the nozzle to the lance, ensuring that the attachment is secure.
- Reconnect the lance to the gun and turn on the water supply.
- Turn on the unit and set the lance to the high-pressure setting to test.
How to use detergents or chemicals
To use these products we have to deposit them in a separate tank of which the machine will vacuum them. In this case, we will attach the black nozzle. After completing the task, we must place the tank in clean water separately and extract it through the chemical injection system. If it There are chemicals left in the pump, it could get damaged.
Breakdown and Manual